Medical Device Regulatory Glossary: FDA and EU MDR Terms Explained
Plain-language definitions of the key FDA and EU MDR terms, from 510(k), PMA and QMSR to CE marking, notified body and PRRC, with links to in-depth guides.

Medical device regulation is full of acronyms, and the same word can mean different things in the US and the EU. This glossary gives short, plain definitions of the terms regulatory, quality and clinical teams use most, grouped by topic, with links to the guides that explain each one in depth. Where FDA and EU usage differ, the entry says so.
US pathways and submissions
- 510(k) (premarket notification): a submission showing your device is substantially equivalent to a legally marketed predicate. FDA clears the device. See the 510(k) process.
- Breakthrough Devices Program: a voluntary FDA programme that speeds interaction and review for qualifying devices for life-threatening or irreversibly debilitating conditions. See the Breakthrough guide.
- De Novo: a request for FDA to classify a novel, low-to-moderate risk device with no predicate into Class I or II. See the De Novo guide.
- eSTAR: FDA’s electronic Submission Template And Resource, an interactive PDF used to prepare 510(k) and De Novo submissions.
- HDE (Humanitarian Device Exemption): a route for devices that treat or diagnose conditions affecting a small population.
- IDE (Investigational Device Exemption): permission to use an investigational device in a clinical study to collect safety and effectiveness data. See IDE and clinical studies.
- PMA (Premarket Approval): FDA’s approval route for high-risk Class III devices, based on valid scientific evidence, usually including clinical data. See the PMA guide.
- Pre-Submission (Pre-Sub or Q-Sub): a request for FDA feedback on your plans before you submit. See Pre-Sub meetings.
- Predicate device: a legally marketed device you compare against in a 510(k). See selecting a predicate.
- Substantial equivalence (SE): the 510(k) test: the same intended use, and either the same technological characteristics or different ones that do not raise different questions of safety and effectiveness.
- Special controls: device-specific requirements, beyond general controls, that FDA sets for a Class II device type, for example through a De Novo grant.
- Comparison of pathways: 510(k) vs De Novo vs PMA.
Classification and intended use
- Class I, II, III (US): FDA’s risk-based classes. Class I is lowest risk, Class III highest. See device classification.
- Class I, IIa, IIb, III (EU MDR): the EU’s four risk classes, set by the rules in Annex VIII of the MDR.
- Intended use / indications for use: what the device is for and, in the US, the conditions or population it is for. It drives classification, evidence and labeling.
- Combination product: a product that combines a device with a drug or biologic. See combination products.
- Product code: a three-letter FDA code that groups similar devices and shows how they are regulated.
Quality systems and design
- CAPA (corrective and preventive action): the process for investigating causes of nonconformities and acting to fix and prevent them. See CAPA and complaint handling.
- Design controls: the planned, documented process for design and development, from inputs to outputs, verification, validation and transfer. See design controls.
- DHF, DMR, DHR: the design history file, device master record and device history record from the older Quality System Regulation. The QMSR follows ISO 13485 and its “medical device file” concept, so FDA no longer requires these names, although many companies still use them.
- ISO 13485: the international quality management system standard for medical device organisations. See ISO 13485 and MDSAP.
- MDSAP (Medical Device Single Audit Program): one audit that can satisfy the requirements of several regulators, including the US, Canada, Australia, Brazil and Japan.
- QMSR (Quality Management System Regulation): FDA’s revised 21 CFR Part 820, effective 2 February 2026, which incorporates ISO 13485:2016 by reference. See the QMSR checklist.
- Risk management (ISO 14971): the standard process for identifying, evaluating and controlling risks across the device lifecycle. See risk management.
- Verification vs validation: verification checks that you built the design right (outputs meet inputs). Validation checks that you built the right device (it meets user needs and intended use). Process validation is related but separate. See process validation.
- Usability engineering (IEC 62366): the process for reducing use errors through formative and summative evaluation. See usability engineering.
Software and cybersecurity
- SaMD (Software as a Medical Device): software that is a medical device in its own right, not part of a hardware device. See Is my software a medical device?
- IEC 62304: the standard for the medical device software lifecycle. See the IEC 62304 guide.
- SOUP (software of unknown provenance): software developed elsewhere that you use in a device but did not develop under your own lifecycle controls. See what counts as SOUP.
- PCCP (predetermined change control plan): a plan, authorised by FDA with the device, describing planned future changes and how they will be validated, so they can be made without a new submission. See the PCCP guide.
- CSV / CSA (computer software validation / assurance): approaches to showing that software used in your quality system is fit for its purpose. See CSV and CSA.
Labeling and identification
- Labeling: in the US, labels and other written, printed or graphic material accompanying a device, including instructions. See device labeling requirements.
- UDI (Unique Device Identification): a system for identifying devices through their lifecycle. The UDI-DI identifies the device model and the UDI-PI identifies production details such as lot or serial number. GUDID is FDA’s UDI database. See UDI in the EU and US.
Post-market activity
- Complaint: any communication that alleges a deficiency in a device’s identity, quality, durability, reliability, safety, effectiveness or performance after release.
- FSCA (field safety corrective action): the EU term for action to reduce a risk of death or serious deterioration in health from a device already on the market. The communication to users is a field safety notice. See recalls and FSCAs.
- MDR (Medical Device Reporting), US: FDA’s adverse event reporting requirement under 21 CFR Part 803. See the MDR Part 803 guide. Not the same as the EU MDR.
- PMS (post-market surveillance): the systematic process of collecting and analysing data on devices in use. See post-market surveillance.
- PMCF (post-market clinical follow-up): an EU MDR process to continuously collect clinical data on a CE-marked device in use.
- PSUR (periodic safety update report): an EU MDR report summarising PMS data and conclusions for higher-risk devices.
- Recall: a firm’s action to remove or correct a product that violates the law or presents a risk. In the US, FDA classifies recalls by health hazard.
EU MDR and IVDR
- Authorised representative (EU AR): an EU-based entity appointed by a non-EU manufacturer to act on its behalf. See economic operators.
- CE marking: the mark showing a product meets applicable EU requirements and can be sold in the EU. See EU MDR and IVDR.
- CER (clinical evaluation report) and CEP (clinical evaluation plan): the documents that plan and report the clinical evaluation required for CE marking. See clinical evaluation.
- EUDAMED: the European database for medical devices, with modules for actors, UDI and devices, notified bodies, vigilance and others. See EUDAMED.
- GSPR (General Safety and Performance Requirements): the requirements in Annex I of the MDR that every device must meet.
- IVDR: the EU In Vitro Diagnostic Regulation (EU) 2017/746. See the IVDR guide.
- MDR (EU): Regulation (EU) 2017/745 on medical devices.
- Notified body: an independent organisation designated by an EU country to assess conformity for higher-risk devices. See notified body selection.
- PRRC (Person Responsible for Regulatory Compliance): the person under MDR Article 15 who ensures key compliance tasks are done. See the PRRC guide.
- Technical documentation: the file a manufacturer keeps to show the device meets the MDR, set out in Annexes II and III.
- UKCA: the UK conformity marking. See UK medical device regulation.
Standards and clinical
- Consensus standard: a standard FDA recognises for use in submissions. In the EU, harmonised standards give a presumption of conformity. See standards guide.
- ISO 10993: the series of standards for biological evaluation of devices. See biocompatibility.
- ISO 14155: the standard for good clinical practice in clinical investigations of medical devices in humans.
- IEC 60601: the series of standards for the safety and essential performance of medical electrical equipment. See electrical safety and EMC.
Careers and certification
- RAC (Regulatory Affairs Certification): a credential from RAPS. The Devices exam has 120 multiple-choice questions in 2.5 hours. See what is RAC (Devices)?
- RAPS: the Regulatory Affairs Professionals Society, which offers the RAC. AptSkill MedTech is not affiliated with it.
- Career levels: see the regulatory affairs career path by level.
Frequently asked questions
What is the difference between FDA clearance and approval?
FDA clears a device through a 510(k), grants a De Novo request and approves a PMA. The terms are not interchangeable, and using the wrong one in marketing can be misleading.
Does MDR mean the same thing in the US and the EU?
No. In the EU, MDR is the Medical Device Regulation (EU) 2017/745. In the US, MDR usually means Medical Device Reporting, the adverse event reporting rules in 21 CFR Part 803.
What is the difference between a medical device and SaMD?
SaMD is a type of medical device: software that is intended for a medical purpose and is not part of a hardware medical device. It is regulated as a device because of its intended use, not because of its form.
Is this glossary legal advice?
No. Definitions are simplified to help you learn. For a legal or compliance decision, read the regulation itself and consult a qualified professional.
General information as of November 2026. Regulations and guidance change, so confirm current definitions in the official texts.
Primary sources
Official texts behind the definitions above. Rules and guidance change, so read the current version before relying on any summary.
- 21 CFR Chapter I, Subchapter H (Medical Devices), eCFR
- Regulation (EU) 2017/745 (MDR), EUR-Lex
- Regulation (EU) 2017/746 (IVDR), EUR-Lex
- Overview of Device Regulation, FDA
- ISO 13485:2016, ISO
Talk to the AptSkill team
Need training for your team on these topics? Send us a message.
Ask the AptSkill team
Ready to take the next step?
Questions? Email contact@aptskillmedtech.com and the AptSkill team will respond promptly.