PRRC under EU MDR Article 15: Person Responsible for Regulatory Compliance
Who needs a PRRC, the qualification rules, the five duties, rules for small companies and authorised representatives, and how to document the role.

Every manufacturer that places a device on the EU market under the MDR or IVDR must have a person responsible for regulatory compliance, known as the PRRC. The role is written into Article 15 of both regulations, and it is one of the first things a notified body, a competent authority or an auditor checks. This guide explains who needs a PRRC, what qualifications are required, what the PRRC is responsible for, how small companies and authorised representatives are treated, and how to document the role so that it stands up to review.
Who needs a PRRC
| Organisation | Requirement |
|---|---|
| Manufacturer (not micro or small) | At least one PRRC available within the organisation. |
| Micro or small enterprise manufacturer | Not required to have the PRRC in the organisation, but must have one permanently and continuously at its disposal. |
| Manufacturer of custom-made devices | Same duty, with an alternative route to show expertise based on experience in a relevant field of manufacturing. |
| Authorised representative | At least one PRRC permanently and continuously at its disposal, with expertise in EU regulatory requirements. |
The size categories follow the EU definition of micro and small enterprises. See EU MDR economic operators for the roles of manufacturers, authorised representatives and importers.
Required expertise
The PRRC’s expertise in the field of medical devices must be shown by either of these:
- A diploma or equivalent qualification from a university degree or recognised course of study in law, medicine, pharmacy, engineering or another relevant scientific discipline, and at least one year of professional experience in regulatory affairs or in quality management systems relating to medical devices.
- Four years of professional experience in regulatory affairs or in quality management systems relating to medical devices.
Qualifications are assessed alongside national rules, so confirm how your competent authority and your notified body interpret them.
What the PRRC is responsible for
- Conformity before release. The conformity of each device is appropriately checked under the quality management system before it is released.
- Documentation. The technical documentation and the EU declaration of conformity are drawn up and kept up to date.
- Post-market surveillance. The manufacturer’s PMS obligations are met. See post-market surveillance.
- Vigilance. The reporting obligations for serious incidents and field safety corrective actions are fulfilled.
- Investigational devices. The statement required for devices intended for clinical investigation is issued.
The PRRC does not replace the manufacturer. The manufacturer remains responsible for compliance, and national law governs how professional liability applies to the PRRC. Take legal advice for your situation.
Several PRRCs and delegation
If several people are jointly responsible, their areas of responsibility must be set out in writing. The PRRC must not suffer any disadvantage within the organisation for properly carrying out their duties, whether or not they are an employee. That protection matters most when the PRRC has to hold a release or raise a problem against commercial pressure.
Documenting the role
| Document | What it shows |
|---|---|
| Appointment letter or procedure | Who the PRRC is, from when, and what authority they hold. |
| Evidence of qualification | Degree, CV and years of relevant experience, filed and current. |
| Responsibility matrix | How each Article 15 duty is carried out, by whom, and what record proves it. |
| Release procedure | The conformity check before release and the PRRC’s sign-off or review point. |
| Deputy arrangements | Who covers during absence, with the same qualifications. |
| EUDAMED entry | PRRC details recorded in actor registration. See the EUDAMED guide. |
Common mistakes
- Naming a person who does not meet the qualification or experience test, or cannot show it.
- Treating the role as a signature with no authority to stop a release.
- Using the same single external consultant for several companies without capacity to do the duties.
- Not recording PRRC changes in the quality system and in EUDAMED.
- Assuming the authorised representative’s PRRC covers the manufacturer’s own duty.
- Leaving no cover during holidays or illness.
Frequently asked questions
Can the PRRC be an external consultant?
For micro and small enterprises, the PRRC may be external if permanently and continuously available. Other manufacturers need one within the organisation. See MDCG 2019-7 and check the guidance for your case.
Can the PRRC be located outside the EU?
The regulation does not set the same location rule as for the authorised representative. Read MDCG 2019-7 and ask your notified body how it treats non-EU manufacturers.
Does the same duty apply under the IVDR?
Yes. Article 15 of the IVDR is parallel. See the IVDR guide.
Is a PRRC a good career step?
It is a senior regulatory or quality role in many companies. See the regulatory affairs interview guide for how it is discussed.
Related reading
- EU MDR and IVDR explained: where Article 15 fits.
- EU MDR technical documentation: what the PRRC keeps current.
- Notified body selection: what they ask about the PRRC.
General information as of November 2026. It is not legal advice. Confirm with the current MDR and IVDR text, MDCG 2019-7 and your competent authority.
Talk to the AptSkill team
Need EU MDR training for regulatory and quality staff? Send us your role and goal.
Ask about EU MDR training
Ready to take the next step?
Questions? Email contact@aptskillmedtech.com and the AptSkill team will respond promptly.