FDA 510(k) vs De Novo vs PMA: Which Pathway Does Your Device Need?
A side-by-side comparison of the three FDA premarket routes, with FY2027 fees, review goals, a five-question decision path and how to avoid choosing the wrong one.

Every new device sold in the United States needs a route to market, and the three main FDA premarket routes are 510(k) clearance, De Novo classification and Premarket Approval (PMA). They answer different questions. A 510(k) asks whether your device is substantially equivalent to one already on the market. A De Novo asks FDA to create a new, lower-risk classification for a device with no predicate. A PMA asks FDA to approve a high-risk device on the strength of its own clinical evidence. This guide helps you work out which one applies, side by side, and what to do when it is not obvious.
The three pathways side by side
| 510(k) | De Novo | PMA | |
|---|---|---|---|
| What FDA decides | Substantially equivalent to a predicate: cleared | Classify into Class I or II with special controls: granted | Reasonable assurance of safety and effectiveness: approved |
| Typical device risk | Low to moderate (mostly Class II) | Low to moderate, but novel | High (Class III) |
| Predicate needed? | Yes | No suitable predicate | No |
| Evidence | Comparison to predicate, with performance testing | Risk analysis, performance data and proposed special controls | Valid scientific evidence, usually including clinical data |
| FY2027 standard fee | $28,653 | $191,020 | $636,732 |
| FY2027 small business fee | $7,163 | $47,755 | $159,183 |
| FDA review goal (MDUFA V) | 90 FDA days for most | 150 FDA days for most | Statutory period is 180 days; real elapsed time is usually longer |
| Result | Your device can be a predicate for others | Creates a new device type and a predicate for others | Approval specific to your device; conditions of approval apply |
| Inspection | Not a premarket condition | Not a premarket condition | Pre-approval inspection of manufacturing is common |
Fees reset every 1 October, and review goals describe FDA’s performance targets, not guaranteed timelines. Confirm current figures on FDA’s website before you plan a budget. For fee detail see the US FDA regulations overview, the De Novo guide and the PMA guide.
A decision path in five questions
- Is the product a medical device? If it is not, none of these routes applies. See Is my software a medical device? for software and device classification for the general test.
- Is the device exempt? Most Class I and some Class II devices are exempt from premarket notification, though other requirements still apply. Check FDA’s exemption list and the classification regulation for your device type.
- Does a legally marketed predicate exist with the same intended use and similar technological characteristics? If yes, and any differences do not raise new questions of safety and effectiveness, go to 510(k). Choosing the predicate carefully matters; see the predicate selection guide.
- No suitable predicate: is the risk low to moderate, so that general controls, or general and special controls, can give reasonable assurance of safety and effectiveness? If yes, go to De Novo.
- Is the risk high, or does the device support or sustain life, or present a potential unreasonable risk of illness or injury? Then expect PMA. A device that treats or diagnoses a condition affecting a small population may qualify for a Humanitarian Device Exemption (HDE) instead.
The result of this path is a working hypothesis, not a decision. FDA’s classification database and product codes show how similar devices were handled, which is the best evidence you have. See the regulatory strategy guide for how to combine this with EU planning.
When each pathway is the right fit
510(k): you have a predicate
The 510(k) is the most common route. You do not need to prove the device is safe and effective from scratch. You show that it is substantially equivalent to a predicate: the same intended use, and either the same technological characteristics or different ones that do not raise different questions of safety and effectiveness, supported by performance data. The weakest point is usually the predicate argument itself. A predicate that is a poor match, or that has a recall history, invites questions. See 510(k) deficiency letters.
De Novo: no predicate, manageable risk
De Novo suits genuinely novel devices that do not justify the cost and evidence of a PMA. You can go directly to De Novo, or file a 510(k) first and use De Novo after a not substantially equivalent (NSE) decision. The extra work compared with a 510(k) is the risk analysis and the proposed special controls, which become the standard that later devices must meet. A granted De Novo gives competitors a predicate, so factor that into your commercial plan.
PMA: high risk, evidence from your own device
PMA is the most demanding route, with clinical evidence, a manufacturing review, and approval conditions and supplements after approval. It is generally required for Class III devices that do not have a different route. Plan the clinical programme early, since studies often require an IDE for significant risk devices.
Other routes worth knowing
- Exempt devices: no premarket submission, but you still register, list, label and follow the quality system and reporting rules. See establishment registration and device listing.
- Humanitarian Device Exemption (HDE): for devices treating or diagnosing conditions that affect a small population. It has its own conditions on profit and use.
- Breakthrough Devices Program: not a separate pathway. It speeds interaction with FDA for qualifying devices that go through PMA, 510(k) or De Novo. See the Breakthrough guide.
- Combination products: the route depends on the primary mode of action. See combination products.
- Software with a PCCP: AI-enabled devices can be authorised with a predetermined change control plan under any of the three routes. See the PCCP guide.
How to reduce the risk of choosing wrongly
- Search before you decide. Look up your product code and the cleared or granted devices in FDA’s databases. If you find strong matches, you probably have a predicate.
- Ask FDA. A Pre-Submission (Q-Sub) lets you test your route, evidence plan and special controls before you invest in studies.
- Write down the argument. For a 510(k), the predicate comparison. For a De Novo, why existing devices are not suitable. This is the same text FDA will read.
- Plan for the cost of being wrong. A 510(k) that ends in an NSE decision can still be followed by a De Novo, but you will have used time and a fee.
Common mistakes
- Forcing a 510(k) on a novel device by choosing a predicate with a different intended use.
- Choosing De Novo when a reasonable predicate exists, because it feels safer. It costs far more and takes longer.
- Assuming PMA is needed because the device is complex. Complexity is not the test. Risk and controls are.
- Not budgeting for QMSR readiness and design controls, which apply whichever route you take.
Frequently asked questions
What is the main difference between 510(k), De Novo and PMA?
510(k) compares your device to a predicate. De Novo creates a new classification for a novel, lower-risk device with no predicate. PMA approves a high-risk device based on its own evidence, usually including clinical data.
Can I go from a 510(k) to a De Novo?
Yes. If FDA issues a not substantially equivalent decision because no predicate exists, you can submit a De Novo request. You can also go directly to De Novo if you believe there is no predicate.
Is a 510(k) the same as FDA approval?
No. FDA clears devices through the 510(k) and grants De Novo requests. “Approval” is the term for PMA. The distinction matters for how you describe the device in marketing and labeling.
Which pathway is fastest and cheapest?
In general the 510(k), because the fee is lower and the evidence burden is smaller, followed by De Novo and then PMA. Actual speed depends on your preparation and on FDA’s questions.
Do I need all of these for one device?
No. A device follows one premarket route, though changes after clearance or approval may need a new 510(k) or a PMA supplement. See change control.
General information as of November 2026. It does not replace advice from a qualified regulatory professional, and FDA fees, goals and guidance change. Confirm current requirements with FDA before you act.
Primary sources
Official texts and guidance relevant to this page. Rules and guidance change, so read the current version before relying on any summary.
- How to Study and Market Your Device, FDA
- Overview of Device Regulation, FDA
- De Novo Classification Request, FDA
- PMA Approvals, FDA
- 21 CFR Part 807 (including Subpart E, premarket notification), eCFR
- 21 CFR Part 814 (premarket approval), eCFR
- Medical Device User Fee Amendments 2022 (MDUFA V), FDA
Talk to the AptSkill team
Choosing a US pathway for your device, or training your team on FDA submissions? Send us a message.
Ask about FDA submission training
Ready to take the next step?
Questions? Email contact@aptskillmedtech.com and the AptSkill team will respond promptly.