MedTechAptSkill MedTech
Regulatory Affairs Careers

Medical Device Labeling and UDI Interview Questions and Model Answers

Eight labeling and UDI interview questions with model answers and three case studies on label errors, unsupported claims and new package identifiers.

Updated · AptSkill MedTech

Medical Device Labeling and UDI Interview Questions and Model Answers: Regulatory Affairs Careers (AptSkill MedTech)

Labeling and UDI roles sit where regulation, quality and operations meet: a wrong symbol, a missing identifier or an unreviewed change can stop shipments or trigger a recall. Interviewers want to see that you understand what labeling includes, how UDI works in the US and the EU, and how to keep labeling under change control. This guide gives you 8 model questions with answers and three case studies with ideal answers.

What to prepare

Bring a labeling story: a label or IFU you owned, a change you controlled or a UDI problem you solved. Refresh FDA labeling requirements, UDI in the EU and US and EUDAMED. Know which market your target employer sells in, because the interview will follow it.

Eight common questions with model answers

1. What counts as labeling?

Model answer: “Under the US definition, labeling is broader than the label on the package: it includes labels, instructions for use, inserts, package printing and other written or graphic material accompanying the device. The EU uses the terms label and information supplied by the manufacturer. Because labeling can define the intended use, I treat it as a controlled regulatory document, not marketing copy.”

2. What is a UDI and what are its parts?

Model answer: “A unique device identifier is a code on the label and package that identifies the device through distribution and use. It has a device identifier, which identifies the version or model and the labeler, and a production identifier such as lot, serial number, manufacturing date or expiration date, where those appear on the label. It is shown in both easily readable plain text and in a machine-readable form such as a barcode, and it is issued under a system run by an accredited issuing agency such as GS1, HIBCC or ICCBBA.”

3. What is GUDID and what do you submit to it?

Model answer: “The Global Unique Device Identification Database is FDA’s public database of device identification information. The labeler submits the device identifier and defined attributes such as the brand name, version or model, description, whether it is single-use or sterile and the package configuration. Production identifiers are not submitted. I keep GUDID records accurate and updated when the device information changes.”

4. When do you need a new device identifier?

Model answer: “When a change affects the identification of the device, such as a new version or model, a different package quantity or a change that makes the device a different product. A change that only affects a non-identifying attribute may only need a record update. I check the FDA UDI rules and guidance for each case, and document the assessment, because the wrong choice leads to inaccurate data or an unnecessary new DI.”

5. How does UDI work under the EU MDR?

Model answer: “The MDR requires a UDI system based on a Basic UDI-DI, a UDI-DI and a UDI-PI. The Basic UDI-DI is the main access key for the device’s records in the database and in documents such as the certificate and declaration of conformity. Device and UDI data are registered in EUDAMED through its modules. I check the current status of the EUDAMED modules because their mandatory use is phasing in.”

6. How do you control a labeling change?

Model answer: “Through the document and change control system. A change request describes the reason, then regulatory, quality, clinical or engineering functions review it, including whether it affects the intended use, claims, warnings or a submission. The new artwork is proofed against the approved text, translated versions are updated and verified, and the effective date and the disposition of old stock are defined. I keep records so an auditor can see who approved what and when.”

7. What symbols and standards should labeling follow?

Model answer: “ISO 15223-1 defines symbols to be used on medical device labels, and ISO 20417 sets general requirements for information supplied by the manufacturer. Where a symbol is used, the meaning must be explained or covered by the standard. For prescription devices in the US, the statement that federal law restricts the device to sale by or on the order of a licensed practitioner is required, and I check the labeling regulations for other content like the manufacturer’s name and address.”

8. How do you manage translations?

Model answer: “I use qualified translators, review the translated text against the source, control versions together with the source document and verify the final artwork. In the EU, language requirements for the information supplied are set by each member state, so I keep a list for the markets we sell in. A translation error is a labeling error, so it goes through the same change control.”

Case study 1: wrong expiration date format on a label

Scenario: At final inspection of a fictional sterile dressing, you find a batch has the expiration date printed in a format that does not match the UDI encoding on the same label.

Ideal answer: “I would hold the batch and treat it as a nonconformance. I would confirm what is wrong: the printed text, the barcode data or both, and check whether other lots were affected. Then I would find the root cause, perhaps an artwork template or printer setting, and fix it with a CAPA if it is systemic. Depending on whether any product has shipped, I would assess whether a correction or removal needs evaluation. I would document the decision whether to rework the labels or scrap the batch.”

Case study 2: a marketing claim that is not in the cleared labeling

Scenario: Marketing wants to add the phrase “reduces infection rates” to the packaging of a fictional wound dressing cleared for covering wounds only.

Ideal answer: “I would not approve it until regulatory has reviewed it against the cleared intended use and the evidence we have. A claim that implies a new benefit could change the intended use and may need a new submission, and an unsupported claim could make the product misbranded. I would explain this to marketing, offer wording that stays within the cleared labeling and, if the business wants the claim, outline the clinical evidence and the regulatory route it would need.”

Case study 3: a new package size without a new identifier

Scenario: Operations plans to sell a fictional catheter in a box of 20 instead of 10 and reuse the existing UDI because “the device itself has not changed.”

Ideal answer: “A different package quantity is a different packaging level, and I would expect it to need its own device identifier under the UDI rules, with its own GUDID record. I would check the rules, document the assessment and update the label artwork, the barcode and the database before release. I would also tell the EU team so the UDI-DI and EUDAMED records are updated for the markets we sell in. Reusing the old identifier would create inaccurate traceability.”

Mistakes to avoid

  • Treating labeling as a design or marketing task rather than a controlled regulatory document.
  • Mixing up the device identifier and the production identifier.
  • Forgetting that a claim on a label can change the intended use.
  • Updating artwork without updating translations, GUDID or EUDAMED.
  • Quoting EUDAMED deadlines from memory instead of checking the current position.

Frequently asked questions

Is this a regulatory or a quality role?

Both. Labeling specialists often sit in regulatory affairs or quality, working with engineering, marketing and operations. Check the job description to see who owns artwork, UDI data and approvals.

Do I need to know software for artwork or UDI databases?

Many employers use a labeling or master data system. Experience with artwork tools, barcode verification or product information systems is a plus, but the interview will focus on the regulatory logic.

What other interview guides should I read?

Try the RA questions by level, QA interview guide and our career mentoring roadmap.

Model answers are examples; adapt them to your real experience. Products in the case studies are fictional and for teaching only. Confirm UDI and labeling requirements against the current regulations and guidance.