MedTechAptSkill MedTech
Regulatory Affairs Careers

Human Factors and Usability Engineer Interview Questions for Medical Devices

Eight human factors interview questions with model answers and three case studies: formative findings, a summative failure on a critical task and users missing from the plan.

Updated · AptSkill MedTech

Human Factors and Usability Engineer Interview Questions for Medical Devices: Regulatory Affairs Careers (AptSkill MedTech)

Human factors engineers answer one question for the whole company: can the intended users, in the real use environment, use this device safely and effectively? Interviewers for usability and human factors roles want to see that you understand use-related risk, not only how to run a study. This guide gives you 8 model questions with answers and three case studies with ideal answers, covering IEC 62366-1, FDA human factors expectations, formative and summative testing and the link to risk management.

What to prepare

Bring one usability story you can tell end to end: the users and use environment, the critical tasks, what formative testing revealed, what you changed and how the summative evaluation went. Refresh IEC 62366-1 usability engineering, ISO 14971 risk management and design controls, because human factors questions often cross into all three. Be ready to say which parts of the work you did yourself and which your team or a consultancy did.

Eight common questions with model answers

1. What is the difference between a use error and a user error?

Model answer: “A use error is an action or omission that leads to a result different from what the manufacturer intended or the user expected. The term deliberately avoids blaming the person, because most use errors trace back to a design that made the wrong action easy or the right action unclear. ‘User error’ sounds like the user’s fault and closes the conversation. In my work I look for the design cause, such as a confusing display, a similar-looking connector or instructions that do not match the task, and fix that.”

2. Walk me through the usability engineering process.

Model answer: “I start by defining the intended use, users, use environments and user interface characteristics. I then identify hazards and hazardous situations related to use, build a task analysis and mark the tasks that could cause harm if performed incorrectly, which are the critical tasks. I design the interface, test it formatively and iterate. Once the design is stable, I run a summative evaluation with representative users and critical tasks, analyse every use error and document the result in the usability engineering file, which feeds the risk management file and the submission.”

3. What is a critical task?

Model answer: “A task where incorrect or missed performance could cause serious harm to the patient or user. I identify them from the use-related risk analysis, not from guesswork, and I trace each one to a hazard. Critical tasks drive the summative protocol: every one must be observed, and every use error, close call or difficulty on a critical task must be understood and analysed.”

4. What is the difference between formative and summative evaluation?

Model answer: “Formative evaluations happen during design. They are exploratory and fast, and their goal is to find problems while the design can still change: paper prototypes, mock-ups, cognitive walk-throughs and small tests. The summative evaluation validates a final or production-equivalent design with representative users and realistic use conditions, to show that the device can be used safely and effectively. A summative is not the place to discover new problems. If it does, that is a signal my formative work was too thin.”

5. How do you decide how many participants a summative study needs?

Model answer: “FDA’s human factors guidance recommends at least 15 participants for each distinct user group, so a device used by both lay users and clinicians needs 15 of each. I define the user groups first, because they are defined by characteristics that affect use, such as training, experience, age or physical ability, not by job title alone. I also make sure the sample covers the range of the user population and that participants have not been involved in the design.”

6. A participant makes a use error in the summative study. What do you do?

Model answer: “I do not argue it away. I record what happened, interview the participant on why, and find the root cause: the design, the instructions, the training or the test setup. Then I link it back to the risk analysis and ask whether the residual risk is acceptable or whether a design change is needed. If I change the design in a way that affects that task, I assess whether the change needs further validation. I never dismiss an error as ‘participant did not read the instructions’ without asking why the design relied on reading.”

7. How do instructions for use and training fit in?

Model answer: “They are part of the user interface, but they are the weakest risk control. The preferred order is safety by design first, then protective measures built into the device, and only then information for safety such as labels, instructions or training. If a critical task depends on a warning being read, I treat that as a residual risk that needs strong evidence. In the summative I test the device with the training that real users will actually receive, not an idealised version.”

8. What goes into the human factors section of a submission?

Model answer: “A summary of the intended users, uses and use environments, the identified use-related hazards and critical tasks, the user interface description, the formative work that shaped the design, the summative protocol and results, and the analysis of any use errors with their root causes and any resulting changes. For devices where FDA expects human factors data, such as those with use-related risks of serious harm, a complete human factors report is expected. I always check the current FDA guidance on the content of these reports before writing.”

Case study 1: a near miss in formative testing

Scenario: In a formative test of a fictional home-use infusion pump, two of eight participants confuse the “bolus” and “prime” buttons, which sit next to each other and look alike. The product manager says the instructions already explain the difference.

Ideal answer: “Two of eight is a strong signal at this stage, and it is exactly what formative testing is for. I would treat it as a design problem, not an instructions problem. I would check the hazard analysis to see what happens if the wrong function runs, because that decides how serious this is. Then I would propose design changes, such as separating the buttons, changing their shape and colour or adding a confirmation step for the higher-risk function, and retest the revised design with new participants. I would document the finding, the change and the retest, so it is clear in the usability file how the risk was reduced.”

Case study 2: the summative study shows a failure on a critical task

Scenario: A summative evaluation of a fictional autoinjector shows that 2 of 15 lay users did not hold the device against the skin long enough. The launch date is close.

Ideal answer: “I would not call the study a pass just because 13 of 15 succeeded. I would analyse the root cause of each failure: was the completion signal unclear, was the hold time too long, did the instructions fail? I would map it to the risk analysis to judge the severity of an incomplete dose, then decide with risk management, clinical and regulatory whether the residual risk is acceptable or the design must change. If we change the design, such as adding a clear end-of-dose click and window, I would assess whether it needs a targeted validation. I would tell the team plainly that protecting the launch date is not a reason to accept an unexplained failure on a critical task.”

Case study 3: users who were not in the plan

Scenario: Post-market complaints for a fictional glucose meter show that older adults with reduced dexterity struggle to insert the test strip. Your original user profile did not include them.

Ideal answer: “I would feed this into the post-market process as a new use-related hazard and update the user profile and use-related risk analysis. I would look at the complaints for patterns and severity, then run a focused usability study with the newly identified users to understand the difficulty. Depending on the findings, the response may be a design change, a labelling or training update or both, and I would work with regulatory to decide whether the change needs a new submission or a documented rationale. I would also look at why the original user definition missed this group, so the next project’s profile is better.”

Mistakes to avoid

  • Calling a use error “user error” or blaming participants for not reading the instructions.
  • Running a summative study as if it were exploratory testing.
  • Defining critical tasks by what the team finds important rather than by hazards.
  • Treating labelling and training as the main risk control when a design change is possible.
  • Forgetting that post-market complaints are a human factors input; see post-market surveillance.

Frequently asked questions

Do I need a psychology or engineering degree for human factors roles?

Backgrounds vary: human factors, psychology, biomedical or industrial design engineering and clinical backgrounds are all common. Employers care most about whether you can run a study, analyse use errors and link them to risk.

Which standards should I know?

IEC 62366-1 for the usability engineering process, ISO 14971 for risk management and the FDA human factors guidance. Know how the three connect, and check the current versions before an interview.

What other interview guides should I read?

Try the design and risk interview guide, the product development guide and our career mentoring roadmap.

Model answers are examples; adapt them to your real experience. Devices in the case studies are fictional and for teaching only.

Talk to the AptSkill team

Preparing for a human factors or usability interview? Send us a message.

Ask about interview preparation

Ready to take the next step?

Questions? Email contact@aptskillmedtech.com and the AptSkill team will respond promptly.

Explore RA Courses Contact Us